Test & Screening

Test & Screening

Mil & Space certified screening facility

Centum has an in-house reliability & screening facility which is certified for carrying out tests according to the MIL & Space requirements / specifications.

This test facility includes test systems and equipments for carrying out the following tests.

For more information. Please visit www.rakon.com

Screening Capabilities
Operation Requirements & Conditions Class S
(MIL-PRF-55310
Product level S)
Class B
(MIL-PRF-55310
Product level B)
Engineering Model
Non-Destruct Bond Pull MIL-STD-883, Meth 2023 NA NA
Internal Visual MIL-STD-883, Meth 2017, Class K, Meth 2032, Class K
Stabilization (Vacuum) Bake MIL-STD-883, Meth 1008,
Cond C 150°C,
48 hours min. 24 hours min. If required
Thermal Shock MIL-STD-883, Meth 1011, Cond A NA NA
Temperature Cycle MIL-STD-883, Meth 1010, Cond B, 10 cycles
Constant Acceleration MIL-STD-883, Meth 2001, Cond A, Y1 Plane only, 5000 g’s NA
Seal:Fine Leak MIL-STD-883,Meth 1014,Cond A2
Seal- Gross Leak MIL-STD-202,Meth 112,Cond D
Particle Impact Noise Detection
(PIND)
MIL-STD-883, Meth 2020, Cond B NA NA

Electrical Testing, Pre Burn-In

Input Current-power

Output waveform

Output voltage-power

As specified

MIL-PRF-55310,Par. 4.8.5

MIL-PRF-55310,Par. 4.8.20

MIL-PRF-55310,Par. 4.8.21

Customer PO

     
NA NA
NA NA
NA NA
Customer PO Customer PO Customer PO
Burn-In(load) +125C,nominal supply voltage and burn-in-load, 240 hours minimum 160 hours minimum NA

Electrical Testing, Pre Burn-In

Input Current-power

Output waveform

Output voltage-power

As specified

Nominal and extreme supply voltages,specified load,+23C and temperature extremes

MIL-PRF-55310,Par. 4.8.5

MIL-PRF-55310,Par. 4.8.20

MIL-PRF-55310,Par. 4.8.21

Customer PO

Radiographic Inspection MIL-STD-883, Meth 2012 NA NA

Testing Capabilities
  MIL-STD-202 MIL-STD-883
In- House Testing Method Test Cond. Method Test Cond.
Temperture Cycling 102 C 1010 A,B,C
Humidity 103 A,B    
Moisture Resistance 106   1004  
Thermal Shock 107 All 1011 All
Life 108 A,B,C,D 1005  
Seal 112 All 1014 A,C
Vibration,Sine 204 All   A,B,C
Vibration,Random 214 All 2007  
Radiographic(Real Time) 209   2012 A,B,C,D,E,F
Acceleration 212 A,B,C 2001  
Shock 213 All 2002 A,B
PIND     2020  
Resistance to Soldering Heat 210 B,C    
Aging at Room Temperature        
Aging at Elevated Temperature        
Die Shear Testing     2019  
Terminal Strength 211 A,B,C    
Phase Noise Under Vibration        
g Sensitivity        
Wirebond Pull Testing     2023, 2011  
DPA        
         
Outside Testing        
XRF(no Pure Tin)        
Radiation        
Pyrotechnic Shock(SRS )        
Class S/K Element Evaluation        

Group of Companies

Location

No: 44, KHB Industrial Area,
Yelahanka New Town,
Bangalore - 560 106
India

Tel: +91 80 30046000
Fax: +91 80 30046005

Email: sales@centumelectronics.com
HR Enquiries: HR@centumelectronics.com

Web Development  SnyxiusFacebookLinkedinTwitter